| 注册
首页|期刊导航|强激光与粒子束|大面积X射线分幅变像管的设计

大面积X射线分幅变像管的设计

宗方轲 杨勤劳 顾礼 李翔 张敬金

强激光与粒子束2012,Vol.24Issue(10):2386-2390,5.
强激光与粒子束2012,Vol.24Issue(10):2386-2390,5.DOI:10.3788/HPLPB20122410.2386

大面积X射线分幅变像管的设计

Design of large-format X-ray framing image tube

宗方轲 1杨勤劳 1顾礼 1李翔 1张敬金1

作者信息

  • 1. 深圳大学光电工程学院,深圳大学光电子器件与系统教育部重点实验室,广东深圳518060
  • 折叠

摘要

Abstract

An implementation method of large-format framing image tube is proposed. An electrostatic focusing image tube with large input photocathode and small output image is designed. Coupling with common small-format microchannel plate (MCP) gated framing unit, image gating and enhancement can be realized. Compared to the tube with large-format MCP, this kind of framing tube avoids the high manufacturing cost of lager-format MCP and overcomes the transmission voltage loss and gain uniformity caused by long micro strips. The framing image tube has an effective input working diameter of 100 mm, an output image diameter of 40 mm, and a magnification of 0. 4. The centre spatial resolution is 14. 4 lp/mm, the marginal spatial resolution is 11. 2 lp/mm, and the geometric distortion is less than 15%. The framing characteristic is determined by the MCP framing unit. This method is an effective way for expanding the work area of framing image tubes.

关键词

大工作面积/分幅相机/微通道板选通/变像管/电子光学器件

Key words

large-format/ framing camera/ gated microchannel plate/ image tube/ electro-optical devices

分类

信息技术与安全科学

引用本文复制引用

宗方轲,杨勤劳,顾礼,李翔,张敬金..大面积X射线分幅变像管的设计[J].强激光与粒子束,2012,24(10):2386-2390,5.

强激光与粒子束

OA北大核心CSCDCSTPCD

1001-4322

访问量5
|
下载量0
段落导航相关论文