现代电子技术2012,Vol.35Issue(20):186-188,3.
一种谐波电流超标问题的分析与解决
Analysis and solution of harmonic current over-criterion phenomenon
杨显彬1
作者信息
- 1. 中国西南电子技术研究所,四川成都610036
- 折叠
摘要
Abstract
In electromagnetic compatibility experiments, harmonic current over-criterion phenomenon often exists in the equipments with bridge rectifier filtering circuit. The causes of harmonic current were found out by analyzing this over-criterion phenomenon. Two solutions which are passive power factor correction and active power factor correction are proposed. The advantages and disadvantages of the two methods are analyzed. The experiments proves that the passive power factor correction method can reduce the harmonic current of about 10 dB, and the active power factor correction method can reduce the harmonic current of about 20dB. The two methods can make the original over-criterion equipment to meet the standard requirements. The availability of the two methods was verified.关键词
谐波电流/非线性负载/奇谐函数/功率因数Key words
harmonic current/nonlinear load/odd harmonic function/power factor分类
信息技术与安全科学引用本文复制引用
杨显彬..一种谐波电流超标问题的分析与解决[J].现代电子技术,2012,35(20):186-188,3.