The energy consumption characteristics of major equipments in flue gas desulfurization (FGD) system were analyzed, and the mathematical relationship among energy consumption and several parameters including the unit load, the sulfur content of coal, and the desulfurization efficiency was found. On this basis, we proposed optimization operation ways for energy conservation. Finally taking a typical 1000 MW FGD system as an example, its optimization operation plans were analyzed. Between 40% and 100% boiler maximum continue rate (BMCR) load conditions, neither adding any new equipments, nor having an impact on safe and stable operation of the unit, these optimization operation plans can reduce electricity consumption by 2%~22%. Under most conditions, consumption reduction can reach more than 10%. According to typical load condition estimation, the yearly electric energy can save above 5 052MWh and electricity consumption is decreased by 10.6% when compared with the initial scheme on the basis of the guarantee of the desulfurization effect.关键词
脱硫系统/能耗特性/优化运行/火电机组Key words
desulfurization system/ energy consumption characteristics/ optimization operation/ power unit分类
能源科技引用本文复制引用
徐钢,袁星,杨勇平,陆诗原,黄圣伟,张锴..火电机组烟气脱硫系统的节能优化运行[J].中国电机工程学报,2012,32(32):22-29,前插4,9.基金项目
国家重点基础研究发展计划项目(973计划)(2009CB219801,2011CB710706) (973计划)