中国电力2012,Vol.45Issue(7):42-44,3.
600MW机组轴流式脱硫增压风机变频改造
Retrofit of Variable Frequency on Axial Flue Gas Desulphurization Booster Fan in 600 MW Units
蓝晓村 1夏大伟 1王磊 1安敬学 1孔亮 2仇雷敏3
作者信息
- 1. 河南电力试验研究院,河南郑州450052
- 2. 河南华润电力首阳山有限公司,河南偃师471943
- 3. 郑州新力电力有限公司,河南郑州 450013
- 折叠
摘要
Abstract
The retrofit of variable frequency on an axial flue gas desulphurization (FGD) booster fan in a 600 MW unit has little energy-saving effect and the investment recovery period would be very long. Based on the operation characteristics test of fan, the reason of the problem was analyzed and the optimization scheme was proposed. The application result shows that the scheme has good effect, which can provide a reference for variable frequency retrofit of fan.关键词
轴流风机/运行特性/变频/节能评估Key words
axial fan/ operation characteristics/ variable frequency/ energy-saving estimate分类
能源科技引用本文复制引用
蓝晓村,夏大伟,王磊,安敬学,孔亮,仇雷敏..600MW机组轴流式脱硫增压风机变频改造[J].中国电力,2012,45(7):42-44,3.