应用锥形束CT研究鼻咽癌容积弧形调强放射治疗的摆位误差

尹文晶 孙颖 迟峰 方键蓝 郭蕊 林爱华 祁振宇 马骏

中山大学学报(医学科学版)2012,Vol.33Issue(5):678-682,5.
中山大学学报(医学科学版)2012,Vol.33Issue(5):678-682,5.

应用锥形束CT研究鼻咽癌容积弧形调强放射治疗的摆位误差

Analysis of Inter-fraction and Intra-fraction Setup Error of Nasopharyngeal Carcinoma Patients Treated with Volumetric Modulated Arc Therapy (VMAT) with Cone Beam CT

尹文晶 1孙颖 1迟峰 1方键蓝 1郭蕊 1林爱华 2祁振宇 1马骏1

作者信息

  • 1. 中山大学肿瘤防治中心//华南肿瘤学国家重点实验室放射治疗科,广东广州510060
  • 2. 中山大学公共卫生学院,广东广州510080
  • 折叠

摘要

Abstract

[Objective] To evaluate the inter-fraction and intra-fraction setup error during the treatment with cone beam computer tomography (CBCT) and provide theoretical basis for clinical target volume-planning target volume (CTV-PTV) margins for nasopharyngeal carcinoma patients treated with volumetric-modulated arc: therapy (VMAT). [Methods] Seventeen consecutive NPC patients treated with VMAT were prospectively enrolled for the study between October 2010 and January 2012. For each patient, three CBCT scans were obtained after conventional positioning, online correction with 2 mm tolerance daily and VMAT delivery weekly, and the scans were registered to the planning CT to determine inter-fraction and intra-fraction errors. The MPTV were calculated with the recipe, Vmurin = 2.5Σ + 0.7σ (Σ, systematic error; σ, random error). [Results] The average absolute errors of the pre-correction, post-correction, and intra-fraction error were 1.1-1.2 mm, 0.6-0.7 mm and 0.4-0.6 mm in the three dimensions. The corresponding X were 0.9—1.3 mm, 0.4—0.5 mm and 0.2-0.4 mm, σ were 0.7-0.9 mm, 0.7 mm and 0.5-0.7 mm. Gradual increases in both inter-fraction and intra-fraction three-dimensional (3D) displacement were observed with time and treatment (P = 0.004, P = 0.009). The total MPTV accounting for pre-correction and intra-fraction error were 3.4-4.0 mm and margins accounting for post-correction and intra-fraction error were 1.7—2.3 mm. [Conclusions] VMAT irradiation technology personalized MPTV should be adopted for the design of VMAT plan. Displacement increased as a function of time.

关键词

锥形束断层扫描/摆位误差/计划靶区/鼻咽癌/容积旋转放射治疗

Key words

cone-beam computed tomography/ setup error/ planning target volume/ nasopharyngeal carcinoma/ volumetric modulated arc therapy

分类

医药卫生

引用本文复制引用

尹文晶,孙颖,迟峰,方键蓝,郭蕊,林爱华,祁振宇,马骏..应用锥形束CT研究鼻咽癌容积弧形调强放射治疗的摆位误差[J].中山大学学报(医学科学版),2012,33(5):678-682,5.

基金项目

国家自然科学基金(81071835) (81071835)

卫生部临床学科重点项目(2010178) (2010178)

广东省科技计划项目(2009B030801016) (2009B030801016)

珠江学者(2010) (2010)

中山大学学报(医学科学版)

OA北大核心CSCDCSTPCD

1672-3554

访问量0
|
下载量0
段落导航相关论文