桂林理工大学学报2012,Vol.32Issue(3):411-414,4.DOI:10.3969/j.issn.1674-9057.2012.03.024
某石化公司聚合物框架振动实测与计算
Measurement and Analysis of the Vibration of PP Plant Frame
摘要
Abstract
Significant vibration can be notified in the upper part of pp plant frame while operating in a petrochemical company. In order to ensure the safety of the structure and equipment, the self-vibration characteristics and vibration response of the frame structure are measured in the field. Maximum acceleration is 277 mm/ s . The excitation source is constructed by reverse engineering method. The vibration response of structure is calculated, with a very close to measured result. A plan of adding cross-bracing in the upper part is calculated. The natural frequency of structure is improved to avoid the excitation frequency band. The north-south acceleration amplitude would be reduced 76% while the east-west amplitude would be reduced 28%. The reduction of vibration is remarkable.
关键词
石化/振动/实测/逆向工程/激励Key words
petrochemical/ vibration/ measurement/ reverse engineering/ excitation分类
建筑与水利引用本文复制引用
颜锋,张高明,潘宠平,汤荣伟..某石化公司聚合物框架振动实测与计算[J].桂林理工大学学报,2012,32(3):411-414,4.