计量学报2012,Vol.33Issue(6):505-508,4.DOI:10.3969/j.issn.1000-1158.2012.06.06
逆反射测量标准装置的测量不确定度评定
Uncertainty Evaluation of Retroreflection Measurement Standard Equipment
摘要
Abstract
A study on the measuring principle and process of retroreflection standard equipment was carried out, and two mathematical models, coefficient of luminous intenstiy and coefficient of retroreflection, were established. Then the two models influencing factors were analysed and main sources and distribution characteristics of the measurement uncertainty were founded. According to the theory of uncertainty, uncertainty components were evaluated separately. At last, combined measurement uncertainty was calculated and uncertainty report was proposed. The results show that the measurement uncertainty is 4. 0% or 4. 3% in different values range.关键词
计量学/逆反射/不确定度/计量标准Key words
Metrology/ Retroreflection/ Uncertainty/ Measurement standard分类
通用工业技术引用本文复制引用
朱传征,李伟,杨勇,白媛媛..逆反射测量标准装置的测量不确定度评定[J].计量学报,2012,33(6):505-508,4.基金项目
交通运输部西部交通建设科技项目(2009318108) (2009318108)