医疗卫生装备2012,Vol.33Issue(11):67-68,77,3.
骨盆平片如何分析术后早期的人工全髋关节
Early Postoperative Analysis of Total Hip Replacement by Pelvic Plain Film
陈剑燕 1李天然 1林奇益 2陈凯 1杨平生 1郑向东 1张敏1
作者信息
- 1. 南京军区福州总医院95临床部放射科,福建莆田351100
- 2. 南京军区福州总医院95临床部骨科中心,福建莆田351100
- 折叠
摘要
Abstract
Objective To analyze the type, location and stability of artificial total hip prosthesis by pelvic plain film. Methods Pelvic plain films two to three days after total hip replacement of 50 patients were reviewed retrospectively. Results Of the 52 cementless prostheses, 35 ones underwent successful replacement, 8 ones with metal acetabular abduction angles wider than 50°, 8 ones with a length difference of both lower extremities more than 10mm and one with metal acetabular inward prominent. There were two ones with over-wide metal acetabular abduction angles and both extremities of different lengths. Conchusion Pelvic plain film is effective for the evaluation of total hip replacement. 关键词
人工全髋关节/置换术后/骨盆平片/测量Key words
artificial total hip/ post replacement/ pelvic plain film/ measurement分类