A variable condition calculation method based on improved Flugel equation for cogeneration units was introduced to study the thermal characteristics of those units. This method was applied on the specific units and the calculation result was compared with the experimental data to verify the calculation accuracy. Also, a scheme of optimal load distribution for the cogeneration units was given by dividing the load distribution into two parts: thermal load and electrical load, and dispatching the electrical load according to the thermal load. Simultaneously, this scheme considered the variation of the thermal power coefficient, and the heat consumption minimization was considered as an optimization variable of electrical load distribution. In addition, the diagram of thermoelectric relationship was established on the basis of the thermal characteristics of specific units so that the limitation of load dispatching could be taken into consideration. The comparison between the proposed scheme and other ones indicates that this scheme can decrease the total heat consumption effectively and thus has a better performance. Therefore, this new method can offer the power plants and power dispatch departments a more advisable solution of the load dispatching.关键词