| 注册
首页|期刊导航|中华医学杂志(英文版)|Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring

Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring

LUO Wei ZHANG Fan LIU Tie DU Xing-li CHEN An-ming LI Feng

中华医学杂志(英文版)2012,Vol.125Issue(22):3947-3951,5.
中华医学杂志(英文版)2012,Vol.125Issue(22):3947-3951,5.DOI:10.3760/cma.j.issn.0366-6999.2012.22.006

Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring

Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring

LUO Wei 1ZHANG Fan 2LIU Tie 3DU Xing-li 1CHEN An-ming 1LI Feng1

作者信息

  • 1. Department of Orthopaedics,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Wuhan,Hubei 430030,China
  • 2. Department of Orthopaedics,the First People Hospital of Yichang,San-xia University,Yichang,Hubei 443000,China
  • 3. Department of Orthopaedics,Beijing Chaoyang Hospital,Capital Medical University,Beijing 100020,China
  • 折叠

摘要

Abstract

Background Minimally invasive techniques are gaining wide-spread application in lumbar fusion surgery,because they may have advantage over conventional open surgery in approach-related morbidity.This research was aimed to evaluate the safety and accuracy of the techniques of minimally invasive transforaminal lumbar interbody fusion by using a computer-assisted spinal navigation system combined with electromyography monitoring.Methods Sixteen patients underwent minimally invasive transforaminal lumbar interbody fusion.A computer-assisted spinal navigation system and electromyography were used for guiding pedicle screw placement.The operative duration,blood loss,complications,and fluoroscopic time were recorded.Clinical outcome was assessed by Visual Analog Scale and Oswestry Disability Index.Radiographic images were obtained to evaluate the accuracy of pedicle screw placement and fusion rates.Results The Visual Analog Scale and Oswestry Disability Index scores were vastly improved postoperatively.A total of 64 pedicle screws were implanted and three were regarded as misplacement by post-operative CT scan.Three screw trajectories were adjusted according to intra-operative stimulus-evoked electromyography monitoring.The average fluoroscopy time in each patient was 31.8 seconds,which equals to 7.9 seconds per pedicle screw.No patients had instrument related neurological complications,infection,implant failure or revision.Successful fusion was found in all patients.Conclusions The combination of navigation system and real-time electromyography monitoring can make the minimally invasive operation more safe and accurate while decreasing radiation exposure time of the medical staff and patient and minimizing the chance and the degree of the pedicle screw misplacement.

关键词

minimally invasive spine surgery/computer-assisted navigation/transforaminal lumbar interbody fusion/electromyographic monitoring

Key words

minimally invasive spine surgery/computer-assisted navigation/transforaminal lumbar interbody fusion/electromyographic monitoring

引用本文复制引用

LUO Wei,ZHANG Fan,LIU Tie,DU Xing-li,CHEN An-ming,LI Feng..Minimally invasive transforaminal lumbar interbody fusion aided with computer-assisted spinal navigation system combined with electromyography monitoring[J].中华医学杂志(英文版),2012,125(22):3947-3951,5.

基金项目

This study was supported by a grant from the National Natural Science Foundation of China(No.30772206). (No.30772206)

中华医学杂志(英文版)

OACSCDCSTPCDMEDLINESCI

0366-6999

访问量0
|
下载量0
段落导航相关论文