| 注册
首页|期刊导航|解放军医学杂志|环境低温对失血性休克猪血流动力学及氧动力学的影响

环境低温对失血性休克猪血流动力学及氧动力学的影响

张雪峰 张成 高广荣 蒋会勇 吕晨光 张宝磊 谢名双 张智丽 余莉

解放军医学杂志2013,Vol.38Issue(2):94-98,5.
解放军医学杂志2013,Vol.38Issue(2):94-98,5.

环境低温对失血性休克猪血流动力学及氧动力学的影响

Effects of low ambient temperature on hemodynamics and oxygen dynamics in a porcine hemorrhagic shock model

张雪峰 1张成 1高广荣 1蒋会勇 1吕晨光 1张宝磊 1谢名双 1张智丽 1余莉1

作者信息

  • 1. 110016沈阳 沈阳军区总医院普通外科
  • 折叠

摘要

Abstract

Objective To investigate the effects of low ambient temperature on hemodynamics and oxygen dynamics in a porcine hemorrhagic shock model. Methods Thirty-two healthy adult Bama miniature pigs were randomly divided into four groups (8 each): control (group C), shock under room temperature (22℃, group R), shock under low ambient temperature (-10℃, group L) and shock under normal body temperature (keep pulmonary arterial temperature ranged from 38.5 to 39.5℃, group N). The hemorrhagic shock model was reproduced by venous bleeding (40% of total blood volume), and the core temperature (pulmonary arterial temperature and rectal temperature), heart rate (HR), mean arterial pressure (MAP), pulmonary arterial pressure (PAP), pulmonary arterial wedge pressure (PAWP), central venous pressure (CVP), cardiac output (CO), hemoglobin (Hb), saturation of mixed venous blood (SvO2) and blood gas analysis were recorded before reproduction of shock and at different time points after hemorrhagic shock. The whole body oxygen delivery index (DO2I), oxygen uptake index (VO2I), and oxygen extraction ratio (O2ER) were calculated. Results Four pigs died in group N during the experiment, meanwhile, no pig died in other groups. The core temperature in group C, R and L decreased significantly compared with group N (P<0.05), and the core temperature in group L was significantly lower than that in groups C and R from 120 minutes after shock. No difference was found in hemodynamics, oxygen dynamics and prognosis between group R and group L. The HR and VO2I in group N were significantly higher than those in group L and group R, while there was no difference in other indices between the 3 groups. Conclusion The hemodynamics and oxygen dynamics indices don't worsen in hemorrhagic shock pigs under low ambient temperature, possibly resulting from induced hypothermia caused by anesthesia.

关键词

休克,出血性/温度/血液动力学现象/血气分析

Key words

shock, hemorrhagic/ temperature/ hemodynamic phenomena/ blood gas analysis

分类

医药卫生

引用本文复制引用

张雪峰,张成,高广荣,蒋会勇,吕晨光,张宝磊,谢名双,张智丽,余莉..环境低温对失血性休克猪血流动力学及氧动力学的影响[J].解放军医学杂志,2013,38(2):94-98,5.

基金项目

全军"十一五"医药卫生科研基金(08G002) (08G002)

解放军医学杂志

OA北大核心CSCDCSTPCD

0577-7402

访问量1
|
下载量0
段落导航相关论文