The picking-up and processing method of micro-current chemical signal need to combine computer hardware with its software. In hardware, logarithm and antilogarithm converters are used to carry out logarithm current-voltage conversion of the micro-current signal, mean-while the transistors is used to compensate the temperature fluctuation in the converter. This will increase the input signal' s dynamic range and improves the signal-noise ratio comprehensively. In software, the Gaussian low-pass filtering processing is employed. The third power mean value filtering is used to approach Gaussian algorithm for increasing the calculation efficiency of the system, and also effectively filtering the blank noise.关键词
对数转换器/反对数转换器/高斯低通滤波/微电流信号Key words
Logarithmic converter/Antilogarithm converter/Gauss low-pass filtering/Micro-current signal分类
信息技术与安全科学引用本文复制引用