| 注册
首页|期刊导航|军事医学|病原微生物实验室实验操作对室内空气产生微生物污染的研究

病原微生物实验室实验操作对室内空气产生微生物污染的研究

温占波 殷喆 董晓凯 陈咏 杜茜 杨文慧 李劲松 胡凌飞 王洁 李娜 张柯

军事医学2013,Vol.37Issue(1):1-5,5.
军事医学2013,Vol.37Issue(1):1-5,5.DOI:10.7644/j.issn.1674-9960.2013.01.001

病原微生物实验室实验操作对室内空气产生微生物污染的研究

Contamination of microbiological aerosol generated by pathogenic microbiological labs

温占波 1殷喆 1董晓凯 1陈咏 2杜茜 1杨文慧 1李劲松 1胡凌飞 1王洁 1李娜 1张柯1

作者信息

  • 1. 军事医学科学院微生物流行病研究所,病原微生物生物安全国家重点实验室,国家生物防护装备工程技术中心,北京100071
  • 2. 中国医学科学院医学生物学研究所,昆明,650118
  • 折叠

摘要

Abstract

Objective To simulate the microbiological aerosol generated by the pathogenic microbiological lab, and to provide scientific data on risk evaluation and protection measures for lab assistants. Methods Serratia marcescens was used as the; indicator microorganism. Many experimental operations and accidental cases were simulated in the; lab,such as mix-up, accidental fail-off, centrifugal operation, centrifugal tube break,injection infection, anatomization of animals and leakage; of a biolsafety cabinet. The risk of microbiological aerosol was analyzed by quantitative air sampling and natural agar sedimentation methods. Results The concentration of microbiological aerosol was different under laboratory conditions. The highest intensity of the microbiological aerosol of mix-up was 1409 CFU/m3 , accidental fall-off was 9346 CFU/m3 , centrifugal operation was <10 CFU/m3 , centrifugal tube break was 138 CFU/m3 , injection infection was more than 8232 CFU/m3 , anatomization of animals was <4 and biological safety cabinet leakagc was above 801 CFU/m3 , respectively. Conclusion The; intensity of the; microbiological aerosol generated by pathogenic microbiological labs varies widely. A high concentration of microbiological aerosol can be; generated in a local environment. Experimental skill training and application of primary respiratory proteetion cquipments should be cmphasized.

关键词

病原微生物/微生物气溶胶/源强/实验室感染

Key words

pathogenic microorganism/microbiological aerosol/intensity of the/source/laboratory infection

分类

医药卫生

引用本文复制引用

温占波,殷喆,董晓凯,陈咏,杜茜,杨文慧,李劲松,胡凌飞,王洁,李娜,张柯..病原微生物实验室实验操作对室内空气产生微生物污染的研究[J].军事医学,2013,37(1):1-5,5.

基金项目

国家科技支撑计划资助项目(2008BAI62B05) (2008BAI62B05)

国家科技重大专项资助项目(2012ZX10004402) (2012ZX10004402)

军事医学

OA北大核心CSCDCSTPCD

1674-9960

访问量4
|
下载量0
段落导航相关论文