摘要
Abstract
Based on the cyclic loading test, the finite element analysis on the hysteretic behaviors of the semi-rigid composite steel frame with steel plate shear wall was conducted to study the load carrying capacity, hysteretic behavior, stress and deformation development process, energy dissipation mechanism and failure mode. The results of analysis and test indicate that the requirement on the joint ductility is lowered by using infilled panels. The cooperative work between the frame and the shear wall is well. It' s an ideal lateral force resisting structural system, which has excellent energy consumption and high safety margin. The finite element simulation of structure stress and deformation development course agrees well with the experimental phenomena. Due to the initial eccentricity, welding residual stress and other reasons, the finite element analysis results of the peak load is close to the test results at elastic stage. The finite element analysis of the peak load is higher than the test results, and the theoretical hysteresis loop is plumper.关键词
钢板剪力墙/半刚接钢框架/数值模拟/滞回曲线/耗能机理Key words
steel plate shear wall/ steel frame with semi-rigid connection/ numerical analysis/ hysteretic loops/ energy dissipation mechanism分类
建筑与水利引用本文复制引用