摘要
Abstract
For problem that a great deal of power loss of explosive-proof three-level converter with high power causes temperature rise and further affects converter performance, the paper analyzed principle, advantages and disadvantages of normal heat dissipation modes of electronic devices, and pointed out that the method using heat pipe combined with forced cold air is fit for heat dissipation of explosive-proof three-level converter with high power of coal mine underground. It also analyzed loss and temperature rise of main power devices of high power converter including IGBT, diode and fast-recovery diode under heat dissipation of heat pipe, and got formula of temperature rise of the power devices. The experimental result showed that error of calculated value according to the formula is in allowable range, which proves feasibility and correctness of the formula.关键词
防爆变频器/散热分析/损耗分析/温升分析/热管散热Key words
explosive-proof converter/ heat dissipation analysis/ loss analysis/ temperature rise analysis/ heat dissipation by use of heat pipe分类
矿业与冶金引用本文复制引用
王昌南,何凤有,田明..大功率三电平防爆变频器散热分析及计算[J].工矿自动化,2013,39(1):88-91,4.基金项目
中央高校基本科研业务费专项资金资助项目(JX111744). (JX111744)