农业机械学报2012,Vol.43Issue(z1):54-58,89,6.DOI:10.6041/j.issn.1000-1298.2012.S0.011
气吸式精密排种器正交试验优化
Orthogonal Experiment Optimization on Air-suction Precision Seed-metering Device
摘要
Abstract
The design of quadratic regression orthogonal rotating experiment was used to test the performance of air-suction precision seed-metering device on the type JPS -12 seed metering performance testing bench. The seeding qualified index was 72.31% -98. 17%. The leaking index was 0.51% ~ 18.7%. The regression equation was received by regression analysis of the test results. 3-D figures were drawn with Matlab. Various effects on the experimental indexes by each factor could be received. The experimental factors were optimized, and then the best combination was achieved. When the relative pressure was -2.86 kPa, the hole diameter was 5.2 mm and the speed of seed tray was 21 r/min, the seeding qualified index was 91. 03% and the leaking seed index was 2. 98% .关键词
精密播种/气吸式排种器/试验/优化Key words
Precision seeding/ Air-suction precision seed-metering device/ Experiment/Optimization分类
农业科技引用本文复制引用
王延耀,李建东,王东伟,孙庆卫,杨薇..气吸式精密排种器正交试验优化[J].农业机械学报,2012,43(z1):54-58,89,6.基金项目
国家公益性行业(农业)科研专项资助项目(201203028.1) (农业)