摘要
Abstract
A method is proposed to measure the cryocooler vibration via the Doppler effect. Both axial and radial vibration of a typical G-M RDK-408S cryocooler is measured on the experimental setup. The experimental results indicate that the cryocooler has a working frequency of about 1 Hz. Compared with other directions, the axial direction vibration is the largest, which is about 30 μm, while the radial direction also has pulse vibration, equivalent to that of the axial vibration. The experimental results are much larger than the vibration requirements in inertial confinement fusion research and therefore vibration reduction methods must be adopted.关键词
惯性约束聚变/冷冻靶/制冷机振动/多普勒效应Key words
inertial confinement fusion/ cryogenic target/ cryocooler vibration/ Doppler effect分类
矿业与冶金引用本文复制引用
马坤全,梅鲁生,刘元琼,王凯,林伟,黎军,谢端,雷海乐..低温制冷机振动测试与分析[J].强激光与粒子束,2013,25(3):637-640,4.基金项目