基于PSO算法的三轴磁强计总量差校正
Calibration of tri-axial magnetometer based on PSO algorithm
顾庆 1徐斌 1张松勇 1顾伟1
作者信息
- 1. 上海海事大学航运技术与控制工程交通行业重点实验室,上海200135
- 折叠
摘要
Abstract
Tri-axial magnetometers are widely used in measurement of static magnetic fields. The diversionary error caused by non-orthogonality and different sensitivities among three axes is sure to reduce the accuracy of tri-axial magnetometers. There-fore , the calibration of the total measuring error is needed for accurately measuring the modulus value. The mathematic relation between the measured value and ideal value of the tri-axial magnetometer is analyzed, and the mathematic model for error correc-tion is deduced. The objective function with weight factors is proposed. The error parameters are calculated with PSO algorithm. Practical measurement data was used to verify the correctness and effectiveness of the method.关键词
三轴磁强计/总量差/PSO算法/总量差校正Key words
tri-axial magnetometer/total measuring error/PSO algorithm/total error calibration分类
信息技术与安全科学引用本文复制引用
顾庆,徐斌,张松勇,顾伟..基于PSO算法的三轴磁强计总量差校正[J].现代电子技术,2013,36(2):83-85,90,4.