中国电力2012,Vol.45Issue(9):17-21,5.
汽动引风机技术在1000MW级机组上的应用
Application of Steam-Driven Induced Draft Fan to 1 000-MW Units
李毅杰 1孙叶柱 1杨旭明 1雷保明 1姚友江 1蔡纯1
作者信息
摘要
Abstract
Minor turbine drive is adopted by induced draft fans, which can not only avoid large startup current caused by motor drive and instantaneous variation of auxiliary voltage, but also reduce the auxiliary service rate and the losses in the course of energy conversion with high energy-saving efficiency, Taking Haimen Power Plant for example, a scheme adopting steam turbine drive instcad of motor drive with the boost fun and the induced draft fan integrated fora 1 036-MW unit is intrmlueced, which includes the original technical scheme, the operating tactics, the investment revenue and the performance. The scheme adopting the steam-driven induced draft fan could be a reference for other thermal units of the same capacity.关键词
火力发电机组/引风机/小汽机驱动/控制策略/投资效益/节能效果Key words
thermal generation unil/ induced draft fan/ minor steam turbine drive/ operating tactic/ investment revenue/energy-saving effect分类
能源科技引用本文复制引用
李毅杰,孙叶柱,杨旭明,雷保明,姚友江,蔡纯..汽动引风机技术在1000MW级机组上的应用[J].中国电力,2012,45(9):17-21,5.