Based on the distribution characteristics of critical seepage velocity, the analysis on variation characteristics of aquifer parameters, induced by groundwater source heat pump (GWSHP) operation at constant flow and variable flow respectively, was carried out. A case study, which considered the characteristics of building air conditioning load and the distribution characteristics of critical seepage velocity, was analyzed theoretically. The result compared with the constant flow operation, indicates that the influence on the variations of aquifer parameters at variable flow operation is smaller. The reliability of the variable flow operation is superior to constant flow. If the distribution characteristics of critical seepage velocity is considered, the advantage of variable flow operation is more significant.关键词
临界渗透速度/地下水源热泵/变流量Key words
critical seepage velocity/ groundwater source heat pump/ variable flow分类