| 注册
首页|期刊导航|中国电力|首台600 MW超临界W火焰锅炉水动力特性计算及分析

首台600 MW超临界W火焰锅炉水动力特性计算及分析

吴燕华 杨冬 陈功名 陈一平

中国电力2013,Vol.46Issue(2):24-30,7.
中国电力2013,Vol.46Issue(2):24-30,7.

首台600 MW超临界W火焰锅炉水动力特性计算及分析

Calculation and Analysis of Hydrodynamic Characteristics for First 600-MW Supercritical Down-Fired Boiler

吴燕华 1杨冬 1陈功名 1陈一平1

作者信息

  • 折叠

摘要

Abstract

In order to check the security and reliability of the water-wall, the hydrodynamic characteristic computation program is adopted with the operating parameters taken as initial values to calculate the flow rate and outlet temperature of the working substance in a 600-MW boiler of one thermal power plant which is the first supercritical down-fired boiler designed and put into operation in the world. The hydrodynamic characteristics in normal and coking conditions are compared. The overall calculation values of the outlet working substance temperature match well with the operation data, which illustrates that the program is suitable for practical application. The results show that the lower-furnace water-walls with low mass-flux optimized rifled tubes exhibit a strong positive flow response while the upper-furnace water-walls with vertical smooth tubes exhibit an evident negative mass flux response. Compared to the normal condition, in the coking conditions the mass velocities of the coking circuits in the lower furnace decrease with the outlet fluid temperatures of all circuits being decreased.

关键词

超临界机组/W火焰锅炉/水动力特性/结焦

Key words

supercritical unit/down-fired boiler/hydrodynamic characteristic/coking

分类

能源科技

引用本文复制引用

吴燕华,杨冬,陈功名,陈一平..首台600 MW超临界W火焰锅炉水动力特性计算及分析[J].中国电力,2013,46(2):24-30,7.

中国电力

OA北大核心CSCDCSTPCD

1004-9649

访问量0
|
下载量0
段落导航相关论文