Comparing study for the effect of steel floor beam connection types on the structural behavior, construction time needed and cost of hybrid structures with strengthened story is conducted based on an actual project of 52-storey and 224. 8 m high. The result shows that steel beams should be pinned at both ends or pinned with concrete core and rigidly connected with perimeter frame columns in super high-rise hybrid structures. Outrigger of strengthened story may work together with concrete core tube, being part of a new lateral load resisting system of outrigger-core tube. Scheme of pinned connection at both ends can save the cost about ten percent than rigid connection one.

关键词

超高层混合结构/楼面钢梁连接形式/技术经济性分析/加强层/伸臂桁架

Key words

super high-rise hybrid structure/beam connection type/technical economy analysis/strengthened story/outrigger