强激光与粒子束2013,Vol.25Issue(4):822-826,5.DOI:10.3788/HPLPB20132504.0822
高功率二极管端泵浦板条模块波前畸变实验研究
Experiment research on wavefront distortion of high power diode end-pumped slab module
摘要
Abstract
The Nd:YAG slab end-pumped by laser diode arrays features small thermal effect and wavefront distortion. The theoretical analyses show that inhomogeneity of the temperature field and stress field is the main cause of wavefront distortion in the slab gain medium. For the end-pumped conduction cooled slab gain module, we optimized the pump and thermal uniformity by reasonable design and obtained the static wavefront distortion with a peak-valley (PV) value of 0. 22 μm. We tested the wavefront distortion of this module in the double-amplifier experiment device, deriving the PV values of 3. 49 μm without the signal power injection and 0. 59 μm after energy extraction. At the injection power of 3120 W, we obtained an output power of 4660 W and a beam quality value of 3. 88 times the diffraction limit, with an optical-optical efficiency of 27%.关键词
板条/波前畸变/热效应/光束质量/端泵浦Key words
slab/ wavefront distortion/ thermal effect/ beam quality/ end pumping分类
信息技术与安全科学引用本文复制引用
陈月健,王建东,童立新,纪红,高清松..高功率二极管端泵浦板条模块波前畸变实验研究[J].强激光与粒子束,2013,25(4):822-826,5.基金项目
国家自然科学基金项目(10904009,60890201) (10904009,60890201)