The quality of rockfill filling in drainage and plastication areas are taken as the quality detection standard of dam filling in Liyang Pumped—storage Power Station. The main detection indicators of rockfill filling in drainage area include the porosity, the content of particle with a size less than 5 mm and the permeability coefficient, and the secondary indicator is particle gradation. The main detection indicators of rockfill filling in plastication area include the porosity, the content of particle with a size less than 0.075 mm and the permeability coefficient, and the secondary indicator is particle gradation. The detection results show that the rockfills have good gradation and meet the requirements of design and specification. The detection provide a basis for understanding and controlling construction quality in time, and also provide a reference to further quality control and detection of dam filling.关键词