| 注册
首页|期刊导航|水力发电|溧阳抽水蓄能电站上水库面板堆石坝现场爆破和碾压试验

溧阳抽水蓄能电站上水库面板堆石坝现场爆破和碾压试验

占懿 李建虎

水力发电2013,Vol.39Issue(3):84-87,4.
水力发电2013,Vol.39Issue(3):84-87,4.

溧阳抽水蓄能电站上水库面板堆石坝现场爆破和碾压试验

On-site Tests on Blasting and Roller compaction of CFRD in Upper Reservoir of Liyang Pumped-storage Power Station

占懿 1李建虎1

作者信息

  • 折叠

摘要

Abstract

The main dam in upper reservoir of Liyang Pumped—storage Power Station is a concrete face rockfill dam, and the excavated material of lower reservoir in this project is the main filling material source which has a small reserves and complex geological conditions. The on—site blasting and roller compaction tests show that the filling material provided by blasting in lower reservoir can not meet the requirements on particle gradation. Through the dam filling zoning and designed filling parameters are dynamically adjusted. At present, the dam fillings in drainage zone and modulus-increased zone below EL. 185 m are completed, and the monitors show that the filing quality meets design requirements.

关键词

复杂料源/面板堆石坝/爆破/碾压/试验/上水库/溧阳抽水蓄能电站

Key words

complex material sources/ concrete face Lrockfill dam/ blasting/ roller compaction/ test/ upper reservoir/ Liyang Pumped-storage Power Station

分类

建筑与水利

引用本文复制引用

占懿,李建虎..溧阳抽水蓄能电站上水库面板堆石坝现场爆破和碾压试验[J].水力发电,2013,39(3):84-87,4.

水力发电

OA北大核心CSTPCD

0559-9342

访问量0
|
下载量0
段落导航相关论文