地质与勘探2013,Vol.49Issue(2):367-372,6.
地下水源热泵系统布井方案分析
Schemes of Well Deployment for the Groundwater-Source Heat Pump System
摘要
Abstract
The phenomenon of heat breakthrough is commonly observed in groundwater - source heat pumping. Different schemes of well deployment, in which distances between pumping wells and injection wells are variable, may cause large temperature changes, and further affect the efficiency of the groundwater - source heat pump system. Based on the actual project of the groundwater - source heat pump system in the Zhengzhou Children Hospital, this paper analyzes different schemes with 1 pumping well and 2 injection wells in the aquifer of fine particles. The results show that the best distance between the wells is about 50 m, and the scheme in which the wells are located along a straight line, the natural groundwater gradient is parallel to the line between the puinping well and the injection well, and the gradient is directed to the injection well, will receive the best results.关键词
水源热泵/布井方案/HST3D/数值模拟/细颗粒含水层Key words
water - source heat pump,well deployment scheme,HST3D,numerical simulation,aquifer of fine particles分类
能源科技引用本文复制引用
田良河..地下水源热泵系统布井方案分析[J].地质与勘探,2013,49(2):367-372,6.基金项目
河南省国土资源厅地质矿产科技攻关项目(豫财招标采购(2006)26402号)资助. (豫财招标采购(2006)