Abstract

With the development of science and technology, medical equipments used in clinical diagnosis plays a very important role, is the STA-compact automatic coagulometer common faults are analyzed, and the fault reasons are discussed. Through practical work in STA-compact full automatic blood coagulation analyzer appears common fault cause analysis, combined with the given examples of troubleshooting for repair. The STA-compact full automatic blood coagulation instrument repair, find the essence of the problem, so in practical work on the service life of equipment, use efficiency is enhanced obviously. Through the introduction of STA-compact fully automatic blood coagulation analyzer system constitute, function and three kinds of common fault, aims to provide the operator of related reference information.