理化检验-物理分册2013,Vol.49Issue(3):200-203,4.
有机热载体炉蛇形管失效原因分析
Failure Cause Analysis of Serpentine Pipe in Organic Heat Transfer Material Heater
摘要
Abstract
By means of metallographic examination, mechanical property testing, chemical examination of heat transfer oil and other methods, the fire cause of an organic heat transfer material heater was analyzed. The results showed that the cause of the accident was carbonization and coking happened in the heat transfer oil with too low labeling, which led to overheating and creep cracks in the serpentine pipe, and tube explosion happened at last.关键词
有机热载体炉/蛇形管/导热油/碳化/结焦/爆管Key words
organic heat transfer material heater/ serpentine pipe/ heat transfer oil/ carbonization/ coking/ tube explosion分类
能源科技引用本文复制引用