不同浓度七氟烷在体外循环中应用对手术室环境的影响

苏建林 李屹壁 阳子华 黄保堂 杨九光

山西医科大学学报2013,Vol.44Issue(6):486-489,4.
山西医科大学学报2013,Vol.44Issue(6):486-489,4.DOI:10.3969/J.ISSN.1007-6611.2013.06.018

不同浓度七氟烷在体外循环中应用对手术室环境的影响

Effect of different concentrations of sevoflurane in cardiopulmonary bypass (CPB) on environmental pollution of operating room

苏建林 1李屹壁 2阳子华 1黄保堂 1杨九光3

作者信息

  • 1. 广西桂林市人民医院麻醉科,桂林541002
  • 2. 广西桂林市兴安县人民医院麻醉科
  • 3. 中国医学科学院,北京协和医学院,阜外心血管病医院体外循环科
  • 折叠

摘要

Abstract

Objective To investigate the effect of different concentrations of sevoflurane on environmental pollution of operating room in cardiopulmonary bypass(CPB).Methods Ninety-nine ASA Ⅱ or Ⅲ patients scheduled for mitral-aortic valve replacement were assigned into three groups according to the concentrations of sevoflurane in CPB:group A (n =34,2% sevoflurane) ; group B (n =33,2.5% sevoflurane) ; group C (n =32,3% sevoflurane).Sevoflurane was blown into the oxygenator in three groups at the beginning of CPB,and was drawn out by central vacuum from the oxygenator air vent at the same time.The gas was collected by gasbag to detect the concentration of sevoflurane in several sites in the laminar flow operating room before the CPB,and 15,30,45,60 min after the sevoflurane was blown.The gas was collected in the sites:doctor of surgery (S),anesthetist (M),circulating nurse (X),perfusionist (T),1 cm above the reservoir(R),the oxygenator air vent (O).Results In group C,the concentration of sevoflurane was increased with the time of insufflating sevoflurane at X site and T site(P <0.05),and the concentration of sevoflurane was nearly to the safe concertration of operating room (2 × 10-6) at T4 ; but there was no significant change in group A and group B.At T3 and T4,the concentrations of sevoflurane at M site and S site in group C were significantly higher than that in group B(P <0.05).At X,T,R,and O sites,the concentrations of sevoflurane were the highest in group C and the lowest in group A (P < 0.01) at the same time.Conclusion When the concentration of sevoflurane is lower than 2.5% in CPB,there was no environmental pollution in the operation room.When the concentration of sevoflurane is higher than 3% in CPB and the time is more than 60 min,the environments at sites of the circulating nurses and perfusionists are polluted possibly.

关键词

七氟醚/体外循环/环境污染

Key words

sevoflurane / cardiopulmonary bypass / environmental pollution

分类

医药卫生

引用本文复制引用

苏建林,李屹壁,阳子华,黄保堂,杨九光..不同浓度七氟烷在体外循环中应用对手术室环境的影响[J].山西医科大学学报,2013,44(6):486-489,4.

山西医科大学学报

OACSTPCD

1007-6611

访问量0
|
下载量0
段落导航相关论文