原子能科学技术2013,Vol.47Issue(6):1044-1047,4.DOI:10.7538/yzk.2013.47.06.1044
锰浴法绝对测量中子源发射率
Absolute Measurement of Neutron Source Emission Rate With Manganese Bath Method
刘毅娜 1王志强 1李春娟 1骆海龙 1汪建清 1陈细林1
作者信息
- 1. 中国原子能科学研究院,北京 102413
- 折叠
摘要
Abstract
The manganese bath method is one of the most widespread and exact method to measure neutron source emission rate (neutron source intensity) absolutely at present.Pouring some 56Mn solution with known activity into the bath,the system efficiency can be obtained from γ counts of 56Mn,which is measured by two NaI(Tl) detectors.From saturated counts of a 241Am-Be(α,n) neutron source in the bath,the source emission rate can be obtained.An standard 241Am-Be(α,n) source which is the transfer source of the CCRI (Ⅲ)-K9.AmBe international key comparison organized by the Comité Consultatif des Rayonnements Ionisants,was measured absolutely with the neutron source emission rate standard equipment (manganese bath method).The result is coincident with the average value of the comparison within the uncertainties,therefore the reliability of the standard equipment is verified.关键词
中子源发射率/绝对测量/锰浴法/国际比对Key words
neutron source emission rate/ absolute measurement/ manganese bath method/ international key comparison分类
能源科技引用本文复制引用
刘毅娜,王志强,李春娟,骆海龙,汪建清,陈细林..锰浴法绝对测量中子源发射率[J].原子能科学技术,2013,47(6):1044-1047,4.