Harmful elements presenting in metal jewelry can not only cause great adverse effects on the health of consumers,but also have a great influence on the production,sales and trading of the jewelry manufacturing industry.Therefore,it is necessary to limit the content of harmful elements in metal jewelry.In this paper the two trace elements of Pb and Cd in replicate jewelry samples were determined by ICP-AES.The authors obtained optimal working parameters of the instrument.The method is simple and rapid with high accuracy.The recovery is in the range of 97.0%-104%,and relative standard deviation is less than 0.55%.关键词