Abstract
A GWHP (groundwater source heat pump) experimental apparatus with superheated vapor heat recovery has been introduced in this paper.In the presetting working conditions (inlet and outlet temperature of the cooling water are respectively 18 ℃ and 29 ℃,inlet and outlet temperature of the chilled water are respectively 12 ℃ and 7 ℃),refrigerating output,compressor power input,COP and EER of the GWHP system with and without superheated vapor heat recovery system have been measured.The research results show that system performance of the GWHP with superheated vapor heat recovery device has been obviously improved comparing with the GWHP without the heat recovery system.关键词
热回收型地下水源热泵/性能研究/COPKey words
heat recovery GWHP/performance study/COP分类
能源科技引用本文复制引用
张超,周光辉,刘寅..热回收型地下水源热泵系统性能研究[J].可再生能源,2013,31(7):93-96,4.基金项目