The ground heat exchange system is an important part of ground source heat pump.Because of difference of ground thermal properties,making ground heat exchanger heat transfer capabilities are quite different,which will directly affect the effectiveness and cost of ground source heat pump system.According to line source model theory the authors have done a ground thermal response test in the engineering project and calculated ground thermal parameters.And proposed an engineering simplification algorithm,which took into account the ground thermal properties and load characteristic of building,the calculation results can be used as the basis for engineering design.