强激光与粒子束2013,Vol.25Issue(9):2389-2392,4.DOI:10.3788/HPLPB20132509.2389
兰州重离子加速器腔体反馈电缆漂移的补偿方法
Compensating method for feedback coaxial line drift of cavity of HIRFL
李强 1高焕英 1李靖 1许哲 2王春晓 2丛岩2
作者信息
- 1. 中国电子科技集团公司第54研究所,石家庄050081
- 2. 中国科学院近代物理研究所,兰州730000
- 折叠
摘要
Abstract
A compensating method for the coaxial line drift due to the temperature change using an additional measuring coaxial line is proposed for the low-level radio frequency(RF) control system of Heavy Ion Research Facility in Lanzhou (HIRFL).We measured the temperature effects on the RF phase and RF loss at the SYV50-2-41 cable with and without using the additional measuring coaxial line,respectively.The measured results show that,the long-term phase instability with compensation can be reduced to 1/50 of the one without compensation; the long-term amplitude drift can be reduced to 1/10 at least.关键词
电缆相位补偿/电缆损耗补偿/长期相位稳定度/长期幅度稳定度Key words
phase compensation/ loss compensation/ long-term phase stability/ long-term amplitude stability分类
能源科技引用本文复制引用
李强,高焕英,李靖,许哲,王春晓,丛岩..兰州重离子加速器腔体反馈电缆漂移的补偿方法[J].强激光与粒子束,2013,25(9):2389-2392,4.