Abstract
The fire monitor generally consists of monitor basement,injection part and operation unit.Horizontal turning angle and pitch angle are the two basic parameters for monitor operation.The flexibility and reliability of its operation is decided by the operation unit.The pressure,flow rate and range are the three basic performance parameters.Particularly the range,it plays a very important role in deciding the fire fighting performance and also is the key parameter to measure the performance of the fire monitor.关键词
消防炮的结构/炮座管径的计算/喷嘴口径的计算/压力、流量和射程Key words
fire fighting/structure of fire monitor/calculation of monitor pipe diameter/calculation of nozzle orifice/pressure, flow rote and range分类