| 注册
首页|期刊导航|机械制造与自动化|消防炮主要结构简析与主要设计参数计算

消防炮主要结构简析与主要设计参数计算

邵大财 张志榜 张世凤

机械制造与自动化2013,Vol.42Issue(3):39-40,49,3.
机械制造与自动化2013,Vol.42Issue(3):39-40,49,3.

消防炮主要结构简析与主要设计参数计算

Aain Structure Analysis and Design Parameters Calculation of Fire Monitor

邵大财 1张志榜 1张世凤1

作者信息

  • 1. 南京消防器材股份有限公司,江苏南京211112
  • 折叠

摘要

Abstract

The fire monitor generally consists of monitor basement,injection part and operation unit.Horizontal turning angle and pitch angle are the two basic parameters for monitor operation.The flexibility and reliability of its operation is decided by the operation unit.The pressure,flow rate and range are the three basic performance parameters.Particularly the range,it plays a very important role in deciding the fire fighting performance and also is the key parameter to measure the performance of the fire monitor.

关键词

消防炮的结构/炮座管径的计算/喷嘴口径的计算/压力、流量和射程

Key words

fire fighting/structure of fire monitor/calculation of monitor pipe diameter/calculation of nozzle orifice/pressure, flow rote and range

分类

机械制造

引用本文复制引用

邵大财,张志榜,张世凤..消防炮主要结构简析与主要设计参数计算[J].机械制造与自动化,2013,42(3):39-40,49,3.

机械制造与自动化

OACSTPCD

1671-5276

访问量0
|
下载量0
段落导航相关论文