| 注册
首页|期刊导航|制冷技术|热力膨胀阀对高速列车空调系统性能的影响分析

热力膨胀阀对高速列车空调系统性能的影响分析

欧阳立芝 郭宝东 王立航

制冷技术Issue(4):15-18,4.
制冷技术Issue(4):15-18,4.DOI:10.3969/j.issn.2095-4468.2012.04.105

热力膨胀阀对高速列车空调系统性能的影响分析

Analysis of the Effect of Thermal Expansion Valve on Characteristics of Air Conditioning System in Fast Train

欧阳立芝 1郭宝东 1王立航1

作者信息

  • 1. 唐山轨道客车有限责任公司,唐山063035
  • 折叠

摘要

Abstract

  In order to investigate the effect of thermal expansion valve (TXV) on the characteristics of air conditioning system in fast train, the TXV static superheat regulation experiment was carried out in one failure air conditioning system of the fast train. During the experiment, the characteristics of air conditioning system were analyzed under different TXV static superheat conditions. The results showed that static superheat increasing can efficiently improve the TXV refrigerant shortage and the refrigerant non-uniform distribution in evaporator, and then increase the evaporator pressure and temperature to solve the problem of insufficient cooling capacity.

关键词

高速列车/空调系统/热力膨胀阀/静态过热度

Key words

Fast Train/Air conditioning system/TXV/Static superheat