  The average thermal conductivity coefficient and thermal resisitence of soil are the key factors that affect the heat transfer performance of underground heat exchanger, the energy-saving and economical efficiency of the ground source heat pump. Based on the theory of line heat source, we get parameters including water temperature of inlet and outlet, through the experiment, and make function fitting with the data so as to work out the thermal conductivity coefficient and some other thermal parameters of soil, which can be consulted to design and apply underground heat exchanger.

关键词

地源热泵/热响应测试/土壤热交换器

Key words

Ground source heat pump/Heat response test/Underground heat exchanger