电网技术Issue(1):3603-3609,7.DOI:10.13335/j.1000-3673.pst.2014.01.001
多馈入和多端交直流系统相互作用因子及其影响因素分析
Analysis on Multi-Infeed Interaction Factor of Multi-Infeed AC/DC System and Multi-Terminal AC/DC System and Its Influencing Factor
摘要
Abstract
The method to solve voltage interaction relationship among commutation buses in multi-infeed AC/DC system and multi-terminal AC/DC system is discussed. On this basis the analytical expression of multi-infeed interaction factor (MIIF) is further researched. Through simulation analysis, the effectiveness and accuracy of the obtained expression of MIIF are validated. Using MIIF expression, the impacts of such factors as load characteristic of AC system, equivalent impedance and coupling impedance of AC system, capacity of reactive power compensation equipment in converter station and DC system on multi-infeed interacting factor are analyzed in depth, and some useful conclusions are obtained.关键词
多馈入交直流系统/多端交直流系统/电压相互影响/相互作用因子/影响因素Key words
multi-infeed AC/DC system/multi-terminal AC/DC system/voltage interaction/multi-infeed interaction factor/influencing factor分类
信息技术与安全科学引用本文复制引用
肖俊,李兴源..多馈入和多端交直流系统相互作用因子及其影响因素分析[J].电网技术,2014,(1):3603-3609,7.基金项目
国家863高技术基金项目(2011AA05A119);国家重点基础研究发展计划项目(973项目)(2013CB228204);国家自然科学基金项目(51037003)。@@@@Project Supported by the National High Technology Research and Development of China(863 Program)(2011AA05A119) (2011AA05A119)
Project Supported by the National Basic Research Program of China(973 Program)(2013CB228204) (973 Program)
Project Supported by National Natural Science Foundation of China(NSFC)(51037003) (NSFC)