Abstract
Aiming at problem of power grid frequency fluctuation caused by substantial fluctuation of load and main parame-ters of the unit in progress of single valve and sequence valve switch with power circuit of the steam turbine in some power plant,this paper analyzes and verifies logic structure,algorithm parameters,valve flow characteristics and power circuit structure.Meanwhile,it proceeds optimization for valve flow characteristics of the steam turbine and finishes smooth switch of single valve and sequence valve.In addition,it realizes safe and economic operation of the unit with various control ways and greatly improve economy and rapidity of the unit.关键词
单阀/顺序阀/负荷波动/功率回路阀门流量Key words
single valve and sequence valve/load fluctuation/valve flow of power circuit分类
能源科技引用本文复制引用