| 注册
首页|期刊导航|计算机工程与应用|基于FMEA和FTA的ZPW-2000A轨道电路可靠性分析

基于FMEA和FTA的ZPW-2000A轨道电路可靠性分析

王文斌 苏宏升

计算机工程与应用Issue(21):245-249,5.
计算机工程与应用Issue(21):245-249,5.DOI:10.3778/j.issn.1002-8331.1302-0024

基于FMEA和FTA的ZPW-2000A轨道电路可靠性分析

Analysis on reliability of ZPW-2000A track circuit based on FMEA and FTA

王文斌 1苏宏升1

作者信息

  • 1. 兰州交通大学 自动化与电气工程学院,兰州 730070
  • 折叠

摘要

Abstract

According to the reliability issues of ZPW-2000A type jointless audio frequency-shift modulated track circuit system, the method of combining Failure Modes and Effect Analysis(FMEA)and Fault Tree Analysis(FTA)is proposed for research and analysis of the system reliability. The system is analyzed and defined, and the FMEA table is completed. All possible failure modes, failure effects, fault detection methods and remedial measures are obtained. The fault tree is built. The minimal cut sets of the fault tree are got, and the qualitative and quantitative analyses of the fault tree are conducted. The weak links of the sys-tem are located by qualitative analysis. The fail probability of roof events, important degree of each minimal cut sets and reliabil-ity index are gained through the quantitative analysis. The validity of the reliability analysis method is verified by comparison with the relevant technical requirements.

关键词

轨道电路/故障模式影像分析/故障树/可靠性

Key words

track circuit/Failure Modes and Effect Analysis(FMEA)/Fault Tree Analysis(FTA)/reliability

分类

交通工程

引用本文复制引用

王文斌,苏宏升..基于FMEA和FTA的ZPW-2000A轨道电路可靠性分析[J].计算机工程与应用,2013,(21):245-249,5.

基金项目

铁道部科技研究开发计划项目(No.2012X003-B)。 ()