摘要

Abstract

Objective To study the effect of storage temperature and time on the detection of NK cells and B-lymphocytes. Methods NK cells and B-lymphocytes in peripheral blood were detected by 6-color flow cytometry. The effect of storage temperature and time on the detection of NK cells and B-lymphocytes was observed. Results No change was found in the number of NK cells and B-lymphocytes in whole blood samples stored at 18℃. The number of NK cells and B-lymphocytes decreased after stored at low or high temperature. The whole blood samples that were fixed with paraformaldehyde and stained with fluorescent antibody could be stored for 7 days. Conclusion Flow cytometry can detect NK cells and B-lymphocytes. The samples can be stored at 18℃for 96 h when it is not able to treat them in time. The treated samples can be stored at 4℃for 7 days.

关键词

自然杀伤细胞/B淋巴细胞/流式细胞术

Key words

natural killer cell/B-lymphocyte/flow cytometry