检验医学与临床Issue(24):3318-3319,2.DOI:10.3969/j.issn.1672-9455.2013.24.033
干湿化学法检测血糖结果的比对分析
Comparitive analysis on blood glucose results between dry chemical method and liquid chemical method
摘要
Abstract
Objective To study the correlation of blood glucose results by dry chemical and liquid chemical a-nalysis ,explore whether these two methods can share a reference interval ,while keep the result consistency . Methods According to EP9-A document request of National Committee for Clinical Laboratory of Standards ,the comparative method(X) was ADVIA2400 ,VITROS FS 5 .1 examination method(Y) ,analyze the correlation between the two methods .Detected the blood sugar level again by these two methods after the dry chemical analysis parame-ters were changed .Results Before changes in the parameters ,the blood sugar level by the two methods correlated well(r2 =0 .999 5) ,however the expected bias(SE) of the different Medicine decide level was greater than the allowa-ble deviation (EA/2 ) .After parameters calibration ,these two methods of blood sugar correlated well too ( r2 =0 .999 7) ,SE was less than EA/2 .Conclusion Dry chemical and liquid chemical analysis have good correlation in blood sugar concentration ,they can share the same reference interval after parameters calibration ,which can be re-ceived in clinic .关键词
干化学法/参考区间/血糖/相关分析/湿化学法Key words
dry chemical analysis/reference interval/blood sugar/correlation analysis/liquid chemi-cal method引用本文复制引用
孙健,蒋廷旺,曹娴..干湿化学法检测血糖结果的比对分析[J].检验医学与临床,2013,(24):3318-3319,2.