In order to improve the running state of GIS equipment evaluation, introduces the main monitoring means it, such as online detection, off-line testing, implementation methods and their combination. According to a 220 kV substation case by testing line monitoring and off-line detection phase matched, and through empirical analysis of successful location of partial discharge signal source, ruled out a partial discharge.