南方电网技术Issue(4):39-42,4.
局部放电在线监测与离线检测在GIS设备状态评价中的应用
The Application of On-line Monitoring and Off-Line Detection of Partial Discharge in GIS Equipment Condition Evaluation
张炜 1吕泽承 1邓雨荣 1陶松梅1
作者信息
- 1. 广西电网公司 电力科学研究院,南宁530023
- 折叠
摘要
Abstract
In order to improve the running state of GIS equipment evaluation, introduces the main monitoring means it, such as online detection, off-line testing, implementation methods and their combination. According to a 220 kV substation case by testing line monitoring and off-line detection phase matched, and through empirical analysis of successful location of partial discharge signal source, ruled out a partial discharge.关键词
状态评价/状态监测/局部放电/气体绝缘金属封闭开关设备Key words
state evaluation/condition monitoring/partial discharge/gas insulated metal enclosed switchgear (GIS)分类
信息技术与安全科学引用本文复制引用
张炜,吕泽承,邓雨荣,陶松梅..局部放电在线监测与离线检测在GIS设备状态评价中的应用[J].南方电网技术,2013,(4):39-42,4.