| 注册
首页|期刊导航|宁夏电力|汽轮机抽汽逆止门异常关闭原因分析及处理

汽轮机抽汽逆止门异常关闭原因分析及处理

尚小军

宁夏电力Issue(5):60-63,4.
宁夏电力Issue(5):60-63,4.DOI:10.3969/j.issn.1672-3643.2013.05.016

汽轮机抽汽逆止门异常关闭原因分析及处理

Cause analysis and treatment of extraction check valve abnormal closing for steam turbine

尚小军1

作者信息

  • 1. 西安华瑞能源设计咨询有限公司,陕西 西安 710025
  • 折叠

摘要

Abstract

Aiming at the problem of No. 1 and No.2 units in a power plant frequently occurring gen-erator trip in operation, causing programmable logic controller (PLC) action, bringing on extraction check valve closing, to make analysis. The analysis result shows that the causes of the problem are power source of protection device get disturbance, the disturbance signal come into PLC through equivalent capacity on J1 and J3 lines, lead to protection device misoperation of generator trip. Afeter improving trip signal line of the original generator, the phenomenon of extraction check valve abnor-mal closing have never appearance.

关键词

抽汽逆止门/PLC/SOE/干扰信号

Key words

extraction check valve/programmable logic controller (PLC)/sequence of event(SOE)/disturbance signal

分类

能源科技

引用本文复制引用

尚小军..汽轮机抽汽逆止门异常关闭原因分析及处理[J].宁夏电力,2013,(5):60-63,4.