实用医学杂志Issue(6):944-946,3.DOI:10.3969/j.issn.1006-5725.2014.06.035
下颌下腺窝骨倒凹锥形束CT测量分析
Measurement and analysis of submandibular fossa by Cone-beam CT
摘要
Abstract
Objective To evaluate the anatomic morphology of submandibular fossa. Methods Cone-beam computed tomography (CBCT) was used to analyze the anatomic morphology of submandibular fossa. Implants of various dimensions were virtually placed into the mandibular 1st and 2nd molar region. Spatial relationships among submandibular fossa , mandibular canal and implant were analyzed. Results The depth of the submandibular fossa was (1.0 ± 0.61)mm in the 1st molar region and (1.5 ± 0.61)mm in the 2nd molar region. There were no significant statistical difference in genders, sides, and tooth loss. The length of the implants was (19.7 ± 3.75)mm (d = 4 mm) and (18.6 ± 3.73)mm (d = 5 mm) in the 1st molar region and (16.2 ± 3.46) mm (d = 4 mm) and (15.2 ± 3.09)mm (d = 5 mm) in the 2nd molar region in patiens with teeth and lingual perforation; the length of the implants was (17.1 ± 3.77)mm (d = 4 mm) and (15.6 ± 3.85)mm (d = 5 mm), and (14.2 ± 4.05)mm (d = 4 mm) and (13.2 ± 4.27)mm (d = 5 mm) in patients with tooth loss, respectively. Conclusions Determination of spatial relationships among submandibular fossa , mandibular canal and implants by using CBCT has important significance in guiding dental implant surgery.关键词
下颌骨/下颌下腺窝/牙种植体/锥形束CTKey words
Mandible/Submandibular fossa/Dental implants/Cone-beam computed tomography引用本文复制引用