冶金动力Issue(11):13-13,18,2.
高值与低值结合的中性点电阻接地方式优越性
The Advantages of Neutral Point Resistance Grounding with Combination of High and Low Values
王雪松1
作者信息
- 1. 通化钢铁股份有限公司动力厂,吉林通化 134000
- 折叠
摘要
Abstract
Adopting resistance grounding at neutral points of power grid is an important way to improve reliability and prevent false protection when fault current burning fault points at instant grounding. To classify by load types, i.e. important loads using high resistance grounding, can constantly operate 2 hours at single-phase grounding to avoid losses caused by sudden power cutoff. Secondary loads use low resistance grounding to rapidly cut out of faults.关键词
电阻接地/高值/低值/结合/可靠性Key words
resistance grounding/how value/low value/combination/reliability分类
信息技术与安全科学引用本文复制引用
王雪松..高值与低值结合的中性点电阻接地方式优越性[J].冶金动力,2013,(11):13-13,18,2.