压力容器Issue(9):54-59,6.DOI:10.3969/j.issn.1001-4837.2013.09.008
聚乙烯管道热熔接头冷焊缺陷的微波检测和真密度测试研究
Microwave Inspection and True Density Measurement for Cold Weld Defect in Thermo-fusion Welds of Polyethylene Piping
摘要
Abstract
Microwave scanning and true density techniques were employed to investigate the cold weld de-fect existing in the thermo -fusion welds of polyethylene (PE) piping.The thermo-fusion welds without defects were firstly inspected by microwave scanning .The resultant microwave scanning images were taken as the references .Then the thermo -fusion welds containing cold weld defects formed under different welding conditions were inspected , and the corresponding scanning images were recorded .The welding problems that lead to the cold weld defects can be distinguished by analyzing the scanning images .True density tests were conducted for different thermo -fusion welds ,the results of which confirm the effective-ness and reliability of microwave scanning in detecting the cold weld defects in the thermo -fusion welds of PE piping .关键词
聚乙烯管道/热熔接头/冷焊缺陷/微波扫描/真密度测试Key words
polyethylene piping/thermo-fusion welds/cold weld defect/microwave scanning/true densi-ty test分类
机械制造引用本文复制引用
祝新伟,潘金平,谭连江..聚乙烯管道热熔接头冷焊缺陷的微波检测和真密度测试研究[J].压力容器,2013,(9):54-59,6.基金项目
国家质检总局科技计划资助 ()