压力容器Issue(12):64-70,7.DOI:10.3969/j.issn.1001-4837.2013.12.010
AP1000蒸汽发生器安装技术
Installation Technology of AP1000 Steam Generator
郑东宏 1王志强 1张明 1门昌华 1胡德全1
作者信息
- 1. 国核工程有限公司,山东海阳 265116
- 折叠
摘要
Abstract
AP1000 nuclear power plant is a 3rd generation advanced passive 1000 MWe pressurized water reactor plant with two loops of reactor coolant systems .Compared with the conventional 2nd generation pressurized water reactor technology ,the steam generator ( SG) of AP1000 has many improved changes concerning SG property features and arrangement requirements for facilities within the nuclear island . Based on these improved changes and relevant installation practices ,the installation technology of AP 1000 SG has been introduced and analyzed including installation preparation ,transportation ,lifting,and instal-lation construction ,etc., with a view to provide a technical reference to the installation of main equip-ments in steam supply system of nuclear power plant .关键词
压水反应堆/蒸汽发生器/安装Key words
pressurized water reactor/steam generator/installation分类
机械制造引用本文复制引用
郑东宏,王志强,张明,门昌华,胡德全..AP1000蒸汽发生器安装技术[J].压力容器,2013,(12):64-70,7.