摘要
Abstract
Objective To explore result of CKMB higher than CK in biochemical tests. Methods In82 cases of CK were normal, but the CKMB results were higher than CK by using biochemical analyzer, and CKMB were detected in the chemiluminescence respectively. While 20 healthy subjects served as control specimens. Results 82 cases of specimens in biochemical analyzer measured the result of CKMB were higher than those in the control group, significant dif erence (P<0.01), there is statistical significance;and the chemiluminescence on the measured CKMB results compared with health control group had no significant dif erence (P>0.05) , no statistical significance. Conclusion Biochemical detection in CKMB were higher than CK results is caused by CKMB reagent method. Reagent in the design not consider the body changes in pathological situations.关键词
肌酸激酶MB同工酶/肌酸激酶/生化检测/化学发光/方法学设计Key words
CKMB/CK/Biochemical detection/Chemiluminescence/Methods study design