原子能科学技术Issue(2):305-309,5.DOI:10.7538/yzk.2014.48.02.0305
AP1000核电站海水循环泵可运行性分析
Operability Analysis of Sea Water Circulation Pump in AP 1000 PWR
摘要
Abstract
The integrated definite element model of vertical circulation pump assembles in AP1000 was built .The static analysis and response spectrum analysis were used for normal design condition and design earthquake condition respectively , and the integrality and operability of pump were evaluated through strength and displacement analysis .The results demonstrate that the 1st lateral natural frequency of the pump is 14.4 Hz ,and the first 4 vibration mode shapes consist of an effective mass ratio of 0.94 in the model under a horizontal excitation load .At the design seismic load condition ,the max combination stress of pump case as the main pressure-bearing container is 203 M Pa ,the max displacement in impeller case is 1.5 mm ,the max combination stress of motor assemble is 1.7 M Pa ,and the max displacement of motor assemble is 0.8 mm , all these results are allowable in design . The analysis results demonstrate that the integrality and operability demands of pump are met in this design .关键词
核电站/地震载荷/泵/有限元分析/可运行性Key words
nuclear power plant/seismic load/pump/finite element analysis/operability分类
机械制造引用本文复制引用
欧鸣雄,严建华,盛绛,施卫东,滕国荣..AP1000核电站海水循环泵可运行性分析[J].原子能科学技术,2014,(2):305-309,5.基金项目
国家科技支撑计划资助项目 ()